> For the complete documentation index, see [llms.txt](https://help.sbtinstruments.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.sbtinstruments.com/item-register/consumables/dilution-liquid-bulk.md).

# Dilution liquid: bulk

5 L of ready-made dilution liquid, with particle-free vials to fill

{% columns %}
{% column %}

<figure><img src="https://4199970748-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FAjOYV4v43T0TFlSRqgAp%2Fuploads%2FL6ZlsTVNWQqqNivaxISO%2FDB01.jpg?alt=media&#x26;token=ba886710-79ff-4474-b197-75ad076125b8" alt=""><figcaption><p>500x empty vials and a 5 L container of dilution liquid.</p></figcaption></figure>

<a href="mailto:sales@sbtinstruments.com" class="button primary" data-icon="envelope">Contact SBT to purchase</a>
{% endcolumn %}

{% column %}
:label: Sales item `DB01`

:package: Enough for **500 dilutions**

:globe\_with\_meridians: Country of origin **Denmark**

:label: HS code `9033.00.90`

:droplet: Contains **5 L**

<i class="fa-bolt-lightning">:bolt-lightning:</i> Conductivity is 1850 ± 50 µS/cm

:thermometer: Store at **room temperature**

<img src="https://4199970748-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FAjOYV4v43T0TFlSRqgAp%2Fuploads%2Fgit-blob-839693694b6b481e0e56980fcc8306e9b5cf2a9d%2Fsymbol--iso--expiry-date.png?alt=media" alt="" data-size="line"> Expires **1 year** from production date

:safety\_vest: No GHS pictograms
{% endcolumn %}
{% endcolumns %}

<table><thead><tr><th width="100">Item no.</th><th width="300">Item</th><th>Details</th></tr></thead><tbody><tr><td><code>DB01</code></td><td>Dilution liquid: bulk (500× dilutions)</td><td><mark style="color:$info;">Ready-made dilution liquid in bulk, with particle-free vials. Requires bottletop dispenser (DD01).</mark></td></tr></tbody></table>

{% hint style="warning" %}
**Bulk liquid is not sterile**

The 5 L container is not sterile. Sterile-filter the liquid immediately before you use it.

Mount a 0.22 µm syringe filter on the dilution dispenser, and the liquid is filtered as it leaves the dispenser, straight into the vial. Any 0.22 µm syringe filter works. SBT can supply one.

Never dispense without a filter, and never pour from the container into a vial.
{% endhint %}

{% hint style="warning" %}
**Do not store filled vials**

Fill only the vials you are about to use. A filled vial must not be kept overnight, because growth develops in it and skews your result.

Cold storage is not a fix. It may slow the growth, but it also takes the conductivity outside the range BactoBox® needs, and the measurement fails.
{% endhint %}

## Bundle contents

<table><thead><tr><th width="106" data-type="number">Quantity</th><th width="110">Item no.</th><th>Item</th></tr></thead><tbody><tr><td>5</td><td><code>VI06</code></td><td><a href="https://help.sbtinstruments.com/item-register/individual-items/empty-vial.md">Empty vial (100×)</a></td></tr><tr><td>1</td><td><code>DL01</code></td><td><a href="https://help.sbtinstruments.com/item-register/individual-items/dilution-liquid-5-l.md">Dilution liquid (5 L)</a></td></tr></tbody></table>

That comes to 500 particle-free vials and 5 L of liquid, so 500 dilutions. A sample that is diluted in two serial 1:100 steps uses two filled vials.

## What else you need

<table><thead><tr><th width="110">Item no.</th><th>Item</th><th>How often</th></tr></thead><tbody><tr><td><code>DD01</code></td><td><a href="https://help.sbtinstruments.com/item-register/accessories/dilution-dispenser.md">Dilution dispenser</a></td><td>Once</td></tr><tr><td><code>SF01</code></td><td><a href="https://help.sbtinstruments.com/item-register/consumables/syringe-filter.md">Syringe filter for dilution dispenser (40×)</a></td><td>One change per operating day</td></tr></tbody></table>

Fill an [empty vial](https://help.sbtinstruments.com/item-register/individual-items/empty-vial.md) with dilution liquid to [make your own dilution vials](https://help.sbtinstruments.com/item-register/accessories/dilution-dispenser/using-the-dilution-dispenser/fill-your-dilution-vials.md). [Test your dilution liquid](https://help.sbtinstruments.com/more/how-to-guides/test-your-dilution-liquid.md) once a day.

{% content-ref url="/pages/uTgQyL0K2VFhyGIr5Q7g" %}
[Using the dilution dispenser](https://help.sbtinstruments.com/item-register/accessories/dilution-dispenser/using-the-dilution-dispenser.md)
{% endcontent-ref %}

## The other way to get dilution vials

Ready-made vials arrive pre-filled and sterile, with no dispenser and no filling step. That is what we recommend for most labs.

{% content-ref url="/pages/zNNnBvleDr2jZXA5Kof0" %}
[Dilution liquid: ready-made vials](https://help.sbtinstruments.com/item-register/consumables/dilution-liquid-ready-made-vials.md)
{% endcontent-ref %}

## Product data sheet

{% file src="/files/CIUqj27BJFMkjFJ97Wb9" %}

## Safety data sheet (SDS)

{% file src="/files/BhVYadyJcljH10BRK1Tg" %}
English
{% endfile %}

{% file src="/files/yZoABwaUCdztefYWAf36" %}
Deutsch
{% endfile %}

{% file src="/files/nDnLId8pQKHKX8WJ95az" %}
Italiano
{% endfile %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.sbtinstruments.com/item-register/consumables/dilution-liquid-bulk.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
