> For the complete documentation index, see [llms.txt](https://help.sbtinstruments.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.sbtinstruments.com/item-register/individual-items/dilution-liquid-5-l.md).

# Dilution liquid (5 L)

Bulk dilution liquid that you filter and fill into empty vials

{% columns %}
{% column %}

<figure><img src="https://4199970748-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FAjOYV4v43T0TFlSRqgAp%2Fuploads%2Fgit-blob-09776d46ed765d0a8704ea9b53181877db6c0698%2Fphoto--dilution-liquid-5-L.png?alt=media" alt=""><figcaption><p>Dilution liquid (5 L)</p></figcaption></figure>

<a href="mailto:sales@sbtinstruments.com" class="button primary" data-icon="envelope">Contact SBT to purchase</a>
{% endcolumn %}

{% column %}
:label: Sales item `DL01`

:package: Fills **500 vials**

:globe\_with\_meridians: Country of origin **Denmark**

:label: HS code `9033.00.90`

:droplet: Contains **5 L**

<i class="fa-bolt-lightning">:bolt-lightning:</i> Conductivity is 1850 ± 50 µS/cm

:thermometer: Store at room temperature

<img src="https://4199970748-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FAjOYV4v43T0TFlSRqgAp%2Fuploads%2Fgit-blob-839693694b6b481e0e56980fcc8306e9b5cf2a9d%2Fsymbol--iso--expiry-date.png?alt=media" alt="" data-size="line"> Expires **1 year** from production date

:safety\_vest: No GHS pictograms
{% endcolumn %}
{% endcolumns %}

<mark style="color:$info;">We sometimes refer to dilution liquid as</mark> *<mark style="color:$info;">diluent</mark>*<mark style="color:$info;">. We use these terms interchangeably.</mark>

{% hint style="warning" %}

## Non-sterile

Always pass the liquid through a 0.22 µm [syringe filter](https://help.sbtinstruments.com/item-register/consumables/syringe-filter.md) immediately before use. Any 0.22 µm syringe filter works. SBT can supply one.
{% endhint %}

## Included in

<table><thead><tr><th width="100">Item no.</th><th width="300">Item</th><th>Details</th></tr></thead><tbody><tr><td><code>DB01</code></td><td><a href="https://help.sbtinstruments.com/item-register/consumables/dilution-liquid-bulk.md">Dilution liquid: bulk (500× dilutions)</a></td><td><mark style="color:$info;">Holds one 5 L container, together with 500 particle-free vials to fill.</mark></td></tr></tbody></table>

## Filling your own vials

Fill an [empty vial](https://help.sbtinstruments.com/item-register/individual-items/empty-vial.md) with dilution liquid to [make your own dilution vials](https://help.sbtinstruments.com/item-register/accessories/dilution-dispenser/using-the-dilution-dispenser/fill-your-dilution-vials.md).

{% hint style="warning" %}
**Do not store filled vials**

Fill only the vials you are about to use. A filled vial must not be kept overnight, because growth develops in it and skews your result.

Cold storage is not a fix. It may slow the growth, but it also takes the conductivity outside the range BactoBox® needs, and the measurement fails.
{% endhint %}

{% content-ref url="/pages/uTgQyL0K2VFhyGIr5Q7g" %}
[Using the dilution dispenser](https://help.sbtinstruments.com/item-register/accessories/dilution-dispenser/using-the-dilution-dispenser.md)
{% endcontent-ref %}

{% hint style="success" %}

## Ready-made vials avoid the filling step

The [dilution vial](https://help.sbtinstruments.com/item-register/individual-items/dilution-vial.md) arrives filtered, conductivity-adjusted, and long-term stable thanks to gamma radiation sterilization. Filling vials yourself introduces [several ways to drift out of range](https://help.sbtinstruments.com/troubleshooting/error-code-on-screen/qc-test-fails/check-your-consumables.md).
{% endhint %}

## Product data sheet

{% file src="/files/CIUqj27BJFMkjFJ97Wb9" %}

## Safety data sheet (SDS)

{% file src="/files/BhVYadyJcljH10BRK1Tg" %}
English
{% endfile %}

{% file src="/files/yZoABwaUCdztefYWAf36" %}
Deutsch
{% endfile %}

{% file src="/files/nDnLId8pQKHKX8WJ95az" %}
Italiano
{% endfile %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.sbtinstruments.com/item-register/individual-items/dilution-liquid-5-l.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.