What the columns mean
What each column shows in Access and in the summary.csv file.
The Measurements page and each measurement group show your measurements as a table, with one row per program run. Some columns only appear in one of them.
Columns
Status
Why a run is unusable, for example Error 3000. Empty for a usable run.
No
Program
The program that ran, for example Measure or Clean.
No
Started at
When the program started.
No
Sampled at
When you took the sample from your culture. Access uses it to calculate calcHPI.
Yes
ID
A short ID for the measurement, for example B72.
No
HPI
Hours post-inoculation, if you want to set the time axis yourself.
Yes
calcHPI
The time axis of the plots, in hours, calculated by Access. See How Access calculates calcHPI.
No
Label
The name of the culture the sample comes from. Plots draw one line per label.
Yes
Cells/mL
The concentration of bacterial cells in your sample vial.
No
Total/mL
The concentration of all particles in your sample vial, cells included.
No
Dilution
The dilution factor of your sample vial.
Yes
Cells/mL × Dil.
The cell concentration of your undiluted sample, calculated as Cells/mL times Dilution.
No
Total/mL × Dil.
The total concentration of your undiluted sample, calculated as Total/mL times Dilution.
No
CFU/mL × Dil.
Your plate count for the undiluted sample. Correlation groups use it.
Yes
OD × Dil.
Your optical density (OD) reading for the undiluted sample. Correlation groups use it.
Yes
Measurement group
The group the measurement belongs to.
Yes
Notes
Your own notes.
Yes
After you edit a value, click Save. See Label your samples.
How Access calculates calcHPI
If HPI has a value, calcHPI uses it.
If HPI is empty, Access calculates calcHPI from Sampled at. Time zero is the first sample with the same Label in the measurement group.
If both HPI and Sampled at are empty, calcHPI stays empty.
Time zero is your first sample, not the moment you inoculated your culture. To count from inoculation, take your first sample right after you inoculate. Or enter the hours post-inoculation in the HPI column.
Fill in HPI for every sample with a label, or for none of them. Your HPI counts from inoculation, but a calculated calcHPI counts from your first sample. A mix can shift points on the time axis.
Unusable runs
Access shows unusable runs in faded grey and leaves them out of plots and reports. A run is unusable if it ended with an error, you stopped it, it failed or was abandoned, or you excluded it.
In the summary.csv file
The summary.csv file from Download summary holds the same runs, newest first. See Export your data. A few columns have other names there.
Start time is Started at. It uses the time zone of your BactoBox®.
Measurement ID is ID. It runs from A00 to Z99 and then starts over.
Flow cell ID is Flow cell, and Classification filename is Classification.
Errors holds the error code and its message. Access shows it as Status.
Total/mL - Cells/mL is the concentration of particles that are not counted as cells.
A result below the detection limit shows as, for example, "<30000". The file also holds technical columns, such as ECC factor and Classification limits, which our support team uses. Missing a column? Update your BactoBox® software.