What the columns mean

What each column shows in Access and in the summary.csv file.

The Measurements page and each measurement group show your measurements as a table, with one row per program run. Some columns only appear in one of them.

Columns

Column
What it shows
You can edit it

Status

Why a run is unusable, for example Error 3000. Empty for a usable run.

No

Program

The program that ran, for example Measure or Clean.

No

Started at

When the program started.

No

Sampled at

When you took the sample from your culture. Access uses it to calculate calcHPI.

Yes

ID

A short ID for the measurement, for example B72.

No

HPI

Hours post-inoculation, if you want to set the time axis yourself.

Yes

calcHPI

The time axis of the plots, in hours, calculated by Access. See How Access calculates calcHPI.

No

Label

The name of the culture the sample comes from. Plots draw one line per label.

Yes

Cells/mL

The concentration of bacterial cells in your sample vial.

No

Total/mL

The concentration of all particles in your sample vial, cells included.

No

Dilution

The dilution factor of your sample vial.

Yes

Cells/mL × Dil.

The cell concentration of your undiluted sample, calculated as Cells/mL times Dilution.

No

Total/mL × Dil.

The total concentration of your undiluted sample, calculated as Total/mL times Dilution.

No

The average size of the cells, as the diameter of a sphere with the same volume, in µm.

No

CFU/mL × Dil.

Your plate count for the undiluted sample. Correlation groups use it.

Yes

OD × Dil.

Your optical density (OD) reading for the undiluted sample. Correlation groups use it.

Yes

Measurement group

The group the measurement belongs to.

Yes

Notes

Your own notes.

Yes

After you edit a value, click Save. See Label your samples.

How Access calculates calcHPI

  1. If HPI has a value, calcHPI uses it.

  2. If HPI is empty, Access calculates calcHPI from Sampled at. Time zero is the first sample with the same Label in the measurement group.

  3. If both HPI and Sampled at are empty, calcHPI stays empty.

Time zero is your first sample, not the moment you inoculated your culture. To count from inoculation, take your first sample right after you inoculate. Or enter the hours post-inoculation in the HPI column.

Fill in HPI for every sample with a label, or for none of them. Your HPI counts from inoculation, but a calculated calcHPI counts from your first sample. A mix can shift points on the time axis.

Unusable runs

Access shows unusable runs in faded grey and leaves them out of plots and reports. A run is unusable if it ended with an error, you stopped it, it failed or was abandoned, or you excluded it.

More columns on the Measurements page

Scroll to the right on the Measurements page to see these columns.

Column
What it shows

Created at

When the measurement group was created.

Software

The software version your BactoBox® ran.

Flow cell

The ID of the flow cell.

Conductivity

The electrical conductivity of your sample vial.

Classification

The measurement regime of the run, for example BacTotal_v2024-10.

In the summary.csv file

The summary.csv file from Download summary holds the same runs, newest first. See Export your data. A few columns have other names there.

  • Start time is Started at. It uses the time zone of your BactoBox®.

  • Measurement ID is ID. It runs from A00 to Z99 and then starts over.

  • Flow cell ID is Flow cell, and Classification filename is Classification.

  • Errors holds the error code and its message. Access shows it as Status.

  • Total/mL - Cells/mL is the concentration of particles that are not counted as cells.

A result below the detection limit shows as, for example, "<30000". The file also holds technical columns, such as ECC factor and Classification limits, which our support team uses. Missing a column? Update your BactoBox® software.