> For the complete documentation index, see [llms.txt](https://help.sbtinstruments.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.sbtinstruments.com/software/buttons-and-menu.md).

# BactoBox® buttons and menu

Run your samples with the four buttons. Open the menu for your history, the extra programs and the settings.

You run your samples with the four buttons on your BactoBox®. The same buttons also sit in Access. See [Run programs from Access](https://help.sbtinstruments.com/more/software/run-programs-from-access.md).

## The four buttons

<figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2Fgit-blob-c787c5df7506c89af998ce3be53b80c5f909a7b8%2FBactoBox-outline-front--A-to-F.png?alt=media" alt="BactoBox seen from above, with the flow cell lid, the screen and the four buttons Measure, Stop, Empty and Clean." width="560"><figcaption><p>Flow cell lid (A) and screen (B). The buttons, and what they do in the menu: <kbd>Measure</kbd> is OK (C), <kbd>Stop</kbd> is back (D), <kbd>Empty</kbd> is down (E) and <kbd>Clean</kbd> is up (F).</p></figcaption></figure>

| Button             | Press                                                                                                                 | Hold for 1 second |
| ------------------ | --------------------------------------------------------------------------------------------------------------------- | ----------------- |
| <kbd>Measure</kbd> | Starts the *Measure* program.                                                                                         | Opens *Programs*. |
| <kbd>Stop</kbd>    | Stops the program that runs. BactoBox® first returns the liquid to the vial.                                          | Opens the menu.   |
| <kbd>Empty</kbd>   | Returns the liquid in the flow path to the vial. You only need it when BactoBox® asks, for example after a power cut. |                   |
| <kbd>Clean</kbd>   | Starts the *Clean* program.                                                                                           |                   |

{% hint style="info" %}
Leave the tubing kit in the vial until BactoBox® has emptied the flow path. Then all the liquid is back in the vial.
{% endhint %}

## The menu

Hold <kbd>Stop</kbd> for 1 second to open the menu. In the menu, the four buttons work as OK, back, down and up. To leave the menu, pick *Home* and press OK.

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FvPZz1pXyftX6Ts2DldEX%2Fbactobox-screen--menu.png?alt=media" alt="The menu with Home, History, Programs and Settings." width="320"><figcaption><p>The menu.</p></figcaption></figure></div>

{% columns %}
{% column %}

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FRZwNJtI53msSSZFjIOco%2Fbactobox-screen--history.png?alt=media" alt="The History screen lists past programs with their time." width="320"><figcaption><p><em>History</em>. Every program you ran, newest first.</p></figcaption></figure></div>
{% endcolumn %}

{% column %}

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FcUryjdu0Uf5P7TbdM3Zc%2Fbactobox-screen--programs.png?alt=media" alt="The Programs screen with QC test, Conductivity and Deep clean." width="320"><figcaption><p><em>Programs</em>. The QC test, conductivity and the deep clean.</p></figcaption></figure></div>
{% endcolumn %}

{% column %}

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FHnwSQTYyOpBp4nj6mFzP%2Fbactobox-screen--settings.png?alt=media" alt="The Settings screen with System info, Time and date, Language and region, and Service." width="320"><figcaption><p><em>Settings</em>. Your device ID, the clock, and reset.</p></figcaption></figure></div>
{% endcolumn %}
{% endcolumns %}

### History

*History* lists every program you ran on your BactoBox®, newest first. For your results with labels and plots, use Access. See [Do measurements in Access](https://help.sbtinstruments.com/everyday-use/do-measurements-in-access.md).

### Programs

Open *Programs* from the menu, or hold <kbd>Measure</kbd> for 1 second.

* *QC test* checks that your BactoBox® measures correctly. See [Run a QC test](https://help.sbtinstruments.com/maintenance/qc-test/run-qc-test.md).
* *Conductivity* measures the electrical conductivity of the liquid in the vial, in µS/cm. The value is not corrected for temperature.
* *Deep clean* runs for 15 minutes or 10 hours. See [Deep clean your setup](https://help.sbtinstruments.com/more/how-to-guides/deep-clean-your-setup.md).

{% hint style="warning" %}
Your BactoBox® may show more programs, for example *Measure with low conductivity*. Use them only after you have agreed it with SBT. [Contact us](https://sbtinstruments.com/contact).
{% endhint %}

### System info

Find it under *Settings* › *System info*.

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FMszFqksGGneQyRcf1uXh%2Fbactobox-screen--network.png?alt=media" alt="The Network screen shows the device ID as Hostname." width="320"><figcaption><p>Your device ID is the <em>Hostname</em> under <em>Network</em>.</p></figcaption></figure></div>

* *Network* shows your device ID, for example bb2241039. Our support team asks for it.
* *Storage* shows how much space is left on your BactoBox®.
* *Legal info* lists the software licences.
* *Versions* shows your hardware and software version.

### Time and date

Find it under *Settings* › *Time and date*.

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FS9k3uvRrXdXJawK2SBnx%2Fbactobox-screen--time-and-date.png?alt=media" alt="The Time and date screen with Set time, Set date and Set time zone." width="320"><figcaption><p>Set the time zone first, then the time and the date.</p></figcaption></figure></div>

1. Pick *Set time zone*. Pick your continent, then your city, and select *Submit*.
2. Pick *Set time*. Change the hour with down and up, and press OK. Do the same for the minutes.
3. Pick *Set date*. Change the year, the month and the day the same way, and select *Submit*.
4. Restart your BactoBox® to apply the changes.

{% hint style="info" %}
Access sets the clock for you each time you connect your BactoBox® to your computer.
{% endhint %}

### Reset

*Service* is mostly for our service team. Under *Settings* › *Service* › *Reset*, you find two actions you cannot undo.

<div data-with-frame="true"><figure><img src="https://1710807222-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F1GbcuPi5f9BbK7GoqDt1%2Fuploads%2FMPuz8UQ6Z2Vx2rkLqAwT%2Fbactobox-screen--reset.png?alt=media" alt="The Reset screen with Customizations and Delete data." width="320"><figcaption><p>The <em>Reset</em> screen.</p></figcaption></figure></div>

* *Delete data* deletes all measurements on your BactoBox®. [Back up your BactoBox®](https://help.sbtinstruments.com/software/software-updates/back-up-and-restore.md) first if you may need them later.
* *Customizations* returns gating and other settings to the factory defaults. Use it only when SBT asks you to.

Press OK to confirm, then restart your BactoBox®.

{% hint style="danger" %}
You cannot undo a reset.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.sbtinstruments.com/software/buttons-and-menu.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.